Mastertrol Mark V Installation Manual

Mastertrol mark v manual. Mastertrol mark v manual Mark v circuit-switcher. Hvac connection for c wire on mastertrol mark v zone control. Rietveld meubels om zelf te maken download Deviant behavior thio 11th edition Sahih muslim download pdf Bisa kdei. Shopsmith Mark V Read, understand and follow the Mark V Owner's Manual and the manual for every power tool you use. Additional warnings, cautions and instructions and operating techniques are provided in the Shopsmith book, Power Tool Woodworking for Everyone. (A copy is included with your new Mark V, and is also available from Shopsmith.). Installation Instructions. The Motor Switch Terminal, Model MST, is a 24 Volt. Ultrasound Ge Logiq 400 Md Manual more. MOTOR TERMINALS ON MASTERTROL MARK IV, V, VII, VIII, X, XXX, AND XXXI. Invertebrate Zoology Lab Manual. Hooking up ecobee3 to existing Mastertrol Mark V system All, I am hoping someone can help me out here with an ecobee3 installation on a current Mastertrol Mark V system. There are 2 MasterTrol Mark V Control boxes next to the furnaces, one for the 2 stats of the Lower basement level and one for the 3 stats on the main and second level. I'm attaching the wiring diagrams for both those control boxes as well.

Mastertrol Mark V Installation Manuals

  • MARK 7 / Mark V
    • Introduction
      Seven Woodworking ToolsInteractive Demo10' Table Saw34' Lathe16 1/2' Drill Press12' Disc SanderHorizontal BoringOver/Under Table RouterOver/Under Table Shaper7 Functions - Train7 Functions - Clock
      BenefitsFeaturesTool ChangeoversShare FeaturesShared SetupsStandard AccessoriesSpecificationsTable ConfigurationsOver or Under TableTable System Comparison8 Reasons WhyEducationGuarantee
      Testimonials
      Request Information Kit
      See Live Mark 7 Demo
      See a Live Online Demonstration & Sales Event
      Purchase and Pricing
      Mark V SupportGetting StartedHistoryDVD's on the Mark VSerial NumbersTrouble Shooting Chart
  • PRODUCTS
    • Product CatalogProduct CatalogNew ProductsProduct Index
      SpecialsCurrent SpecialsSignup for Email Specials
      ServiceService Parts
      OtherShopsmith Gift CardQuick Order FormDownloadable PDF CatalogSearch
  • WOODWORKING RESOURCES
    • Live Online Demonstration & Sales EventSign-UpFree Gift
      Online VideoSawdust SessionsVideo Shop Tips
      Online InformationPower Tool WoodworkingWoodworking TipsIllustrated TipsService Tips
      PlansProject PlansArticles and Projects
      OtherPersonal Home PageShopsmith ForumsOther Shopsmith Sites
  • SUPPORT
  • ABOUT US
  • CONTACT US
    • FAQ
      Contact Us
      Careers at Shopsmith

Mastertrol Mark V Installation Manual Transmission

Voltage and Continuous, Short-Time, and Fault-Closing Ratings

kVAmperes, RMS
Nom.MaxBILCont.Short-TimeFault-Closing,
Duty-Cycle,
One-Time
Mom.3-Second
34.538200120061 00040 00030 000
4648.3250120061 00040 00030 000
6972.5350120061 00040 00030 000
115121550120061 00040 00030 000
138145650120061 00040 00030 000
1600♥70 00043 75040 000
2000♥80 00050 00040 000
161169750120061 00040 00030 000
230242900160070 00043 75040 000
200080 00050 00040 000
3453621300160070 00043 75040 000
200080 00050 00040 000

Mastertrol Mark V Installation Manual Transfer Switch

♥ 1600 and 2000 amperes continuous available in Three-Pole Center-Break style only.
Interrupting Current Ratings for Transformer Switching and Protection

ClassQualificationsMaximum Amperes,
Interrupting RMS
Symmetrical
Parallel SwitchingMax 60-hertz recovery voltage: 90 kV RMS and 150 kV RMS1200/1600/2000
Load Dropping and Magnetizing Current SwitchingTransformers connected to solidly grounded-wye on the primary (Circuit-Switcher) side and delta on the secondary side1200/1600/2000
All other connections of transformers1200/1600/2000
Fault InterruptingPrimary faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than .7000 or 8000
Primary faults with the total connected length of all lines on the source side of the Circuit-Switcher less than.4000 (3000A for 115-kV single-gap Circuit-Switchers)
Secondary faults — all other connections of transformers4000 (3000A for 115-kV single-gap Circuit-Switchers)
Internal faults — see both primary and secondary faults, above

Depending on continuous rating of Circuit-Switcher.
Will switch magnetizing currents associated with such loads.
Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:

System Voltage, kV34.5 thru 69115 and 138161230345
Total Length, Miles715202540


Interrupting Current Ratings for Line Switching and Protection

Mastertrol Mark V Manual

ClassQualificationsMaximum Amperes,
Interrupting RMS
Symmetrical
Load Splitting (Parallel or Loop Switching)Max 60-hertz recovery voltage: 90 kV RMS and 150 kV RMS1200/1600/2000
Load DroppingCircuits with all load-side transformers connected solidly grounded-wye on the primary (Circuit-Switcher) side and delta on the secondary side1200/1600/2000
Circuits with all load-side transformers connected other than as described above.1200/1600/2000
Line DroppingMaximum length of line: 300 miles.
Fault InterruptingLine or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than .7000 or 8000
Line or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher less than .4000 (3000A for 115-kV single-gap Circuit-Switchers)

Depending on continuous rating of Circuit-Switcher.
Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:

System Voltage, kV34.5 thru 69115 and 138161230345
Total Length, Miles715202540


Interrupting Current Ratings for Cable Switching and Protection

ClassQualificationsMaximum Amperes,
Interrupting RMS
Symmetrical
Load Splitting (Parallel or Loop Switching)Max 60-hertz recovery voltage: 90 kV RMS and 150 kV RMS1200/1600/2000
Load DroppingCircuits with all load-side transformers connected solidly grounded-wye on the primary (Circuit-Switcher) side and delta on the secondary side1200/1600/2000
Circuits with all load-side transformers connected other than as described above.1200/1600/2000
Cable Dropping (Charging Current)Shielded and Unshielded Cable550
Fault InterruptingCable or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than .7000 or 8000
Cable or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher less than .4000 (3000A for 115-kV single-gap Circuit-Switchers)

Depending on continuous rating of Circuit-Switcher.
Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:

System Voltage, kV34.5 thru 69115 and 138161230345
Total Length, Miles715202540


Interrupting Current Ratings for Shunt Capacitor Bank Switching and Protection

Installation
ClassQualificationsMaximum Amperes,
Interrupting RMS
Symmetrical
Bank Current SwitchingGrounded capacitor bankApplications on solidly grounded systems through 69 kV1000
All other applications550
Ungrounded capacitor bank550
Fault InterruptingPrimary faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than .7000 or 8000
Primary faults with the total connected length of all lines on the source side of the Circuit-Switcher less than .4000 (3000A for 115-kV single-gap Circuit-Switchers)

Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:

System Voltage, kV34.5 thru 69115 and 138161230345
Total Length, Miles715202540


Interrupting Current Ratings for Reactor Switching and Protection

ClassQualificationsMaximum Amperes,
Interrupting RMS
Symmetrical
Series Reactor SwitchingRefer to the nearest S&C Sales Office.
Shunt Reactor Switching and Protection (Line-Connected or Tertiary Connected Reactors)Reactor Current SwitchingReactor wye-connected with solidly grounded neutral1000
Reactor delta-connected, or wye-connected with ungrounded neutral1000
Fault InterruptingOil-insulated reactors2800
Air-insulated reactors2000